H05V-K Grounding Cable

Flexible Eca-s1a,d1,a1 grounding cable for commercial and industrial installations

Typical Scenarios
Key Specifications
  • Protective earth conductor for commercial and industrial switchgear and distribution panels.
  • Internal wiring or earthing circuits rated 300/500 V.
  • Suitable for dry or semi-protected commercial and industrial environments.
  • Flexible and easy to route in complex installations.
  • CPR Class: Eca
  • Rated Voltage: 300/500 V
  • Conductor Material: Copper
  • Insulation: PVC, flameretardant and durable
  • Temperature Range: -5°C to +70°C
  • Compliance: EN50525, EN50575
Select cable specifications:
Certifications & complance:

Product Highlights

Installation Environment

Suitable for grounding applications in commercial and industrial switchgear, distribution panels, and protective earth circuits. Ideal for protected or semi-protected indoor environments.

Performance & Durability

PVC insulation provides excellent mechanical flexibility, flame-retardant properties, and reliable performance over -5°C to +70°C. Ensures safe and durable grounding connections.

Compliance & Safety

Ecas1a,d1,a1 CPR-rated and compliant with EN50525, EN50575, CE, RoHS, and REACH. Guarantees adherence to regulatory safety requirements and reduced project risk.

Application Areas

Compatible with standard industrial earthing terminals and busbars

Integrates seamlessly with switchgear, distribution equipment, and protective devices

Supports connection in commercial and industrial grounding systems

Technical Data

FAQ

Recommend

CABLE STRUCTURE
  • Bare copper,annealed stranded acc.to EN60228/IEC60228 Class 5
  • Insulation:PVC(TI 3)acc.to EN50363-3

 

TESTS
  • Conductor resistance acc.to EN60228/IEC60228
  • Mechanical tests before and after ageing acc.to EN60811 1-1&1-2
  • Loss of mass acc.to EN60811-3-2 8.1
  • Pressure test at high temperature acc.to EN60811-3-1 8.1
  • Heat shock acc.to EN60811-3-1 9.1
  • Bending test at low temperature acc.to EN60811-1-4 8.1
  • Elongation test at low temperature acc.to EN60811-1-4 8.3
  • Voltage test on completed cable acc.to EN50395 Clause 6
  • Insulation resistance acc.to EN50395 8.1
  • Spark test acc.to EN50395 10.2
  • Long term resistance of insulation to d.c.acc.to EN50395 Clause 9

 

 

Description Nominal cross section m㎡ OD of conductor mm Thickness of insulation mm Diameter of cable mm Approx. weight kg/km  Cable Color
H05V2-K 0.5 0.95 0.6 2.15 8.5
H05V2-K 0.75 1.15 0.6 2.35 11
H05V2-K 1.0 1.3 0.6 2.5 13.5
H05V2-K 1.5 1.6 0.7 3.0 19.5
H05V2-K 2.5 2.0 0.8 3.6 30.5
H05V2-K 4 2.5 0.8 4.1 43.5
H05V2-K 6 3.1 0.8 4.7 62
H05V2-K 10 4.1 1.0 6.1 106
H05V2-K 16 5.5 1.0 7.5 160
H05V2-K 25 6.7 1.2 9.1 246
H05V2-K 35 8.2 1.2 10.6 339
H05V2-K 50 10.0 1.4 12.8 483
H05V2-K 70 11.6 1.4 14.4 668
H05V2-K 95 13.0 1.6 16.2 877
H05V2-K 120 14.4 1.6 17.6 1136

Download TDS

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.

Can LV and MV cables be supplied in the drum lengths shown in our cable schedule?

Requested drum lengths can be reviewed with the cable schedule. What is practical depends on cable dimensions and weight, total quantity, drum capacity and transport or site-handling limits, so the required lengths should be included with the enquiry.

Is there one MOQ for all HORNOUR cable products?

No single MOQ applies across the entire range. The practical quantity depends on the cable type, size, construction, packing and production conditions. Send the actual cable list and quantities and we can confirm the applicable requirement for those items.