H07V-U Solid PVC Wire

H07V-U forms neat, permanent 450/750 V connections where simple routes and compatible terminals favour solid conductors.

Typical Scenarios
Key Specifications
  • Closed conduit circuits
  • Fixed lighting wiring
  • Building power circuits
  • Protected distribution routes

 

  • Rated voltage: 450/750 V
  • Conductor: Class 1 solid copper
  • Insulation: PVC
  • Maximum conductor temperature: +70°C
  • Design standard: EN 50525-2-31

 

Select cable specifications:
Certifications & complance:

Product Highlights

Stable Conduit Wiring

H07V-U uses a solid Class 1 copper conductor for protected 450/750 V circuits in conduit, distribution boards and fixed building wiring. On straightforward routes, the conductor feeds predictably and keeps the shape formed during installation. This makes it well suited to permanent circuits that remain stationary after commissioning.

Repeatable Connections

Solid copper provides a simple contact interface in terminals designed for Class 1 conductors. Consistent stripping, insertion and clamping are useful in distribution equipment with many similar fixed connections, while the conductor holds its position close to terminal rows. This supports orderly installation without the strand-management requirements of a stranded conductor.

Right-Sized Fixed Wiring

Not every fixed circuit benefits from additional conductor flexibility. Where the route is direct and movement after installation is minimal, H07V-U provides a simple Class 1 solution without introducing strands that the application does not need. H07V-R or H07V-K remain available when bends, routing constraints or termination conditions make a stranded conductor more appropriate.

Application Areas

Designed for Building conduits, Lighting circuits, Fixed distribution wiring and Protected switchboard routes.

 

Building conduits

Lighting circuits

Fixed distribution wiring

Protected switchboard routes

Technical Data

FAQ

Recommend

GENERAL DATA
  • PVC single-core fixed wiring conductor according to EN 50525-2-31
  • Nominal voltage: AC U₀/U 450/750 V
  • Test voltage: 2500 V
  • Temperature range: +5°C to +70°C during installation; -30°C to +80°C when fixed
  • Maximum conductor operating temperature: +70°C

 

CABLE STRUCTURE
  • Bare copper conductor, solid, IEC 60228 Class 1
  • Insulation: PVC compound type TI1 according to EN 50363-3

 

TESTS
  • Conductor resistance according to EN / IEC 60228
  • Flame propagation according to EN / IEC 60332-1-2
  • Voltage and insulation-resistance tests according to the applicable EN 50525 / EN 50395 test programme
  • PVC mechanical, ageing and thermal tests according to the applicable EN / IEC 60811 series

 

 

DIMENSIONS

 

Nominal size mm² Insulation mm Nominal OD mm Approx. weight kg/km
1 × 1.5 0.7 2.9 22
1 × 2.5 0.8 3.6 32
1 × 4 0.8 4.1 50
1 × 6 0.8 4.7 71
1 × 10 1.0 5.9 110

Dimensions are nominal and may vary within the applicable product tolerance.

 

Download TDS

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.

Is there one MOQ for all HORNOUR cable products?