N2XY XLPE Power Cable

N2XY combines copper conductors, XLPE insulation and a protective sheath for fixed distribution requiring greater thermal capability.

Typical Scenarios
Key Specifications
  • PV plant AC distribution
  • Commercial building feeders
  • Outdoor fixed power routes
  • Engineered underground installation

 

  • Rated voltage: 0.6/1 kV
  • Conductor: Class 1 or Class 2 copper, by size
  • Insulation: XLPE
  • Outer sheath: PVC
  • Design standard: IEC 60502-1

 

Select cable specifications:
N2XY
Variant:
Certifications & complance:

Product Highlights

XLPE Copper Feeder

N2XY combines copper conductors with XLPE insulation and a PVC outer sheath for fixed 0.6/1 kV power distribution. The XLPE insulation gives the cable a stronger thermal platform than a PVC-insulated NYY construction, making N2XY attractive for feeders where load, grouping or ambient conditions place greater demand on the insulation system.

External and Buried Routes

N2XY can be installed in buildings, ducts, free air and underground where the route is protected from mechanical damage. This makes it useful for commercial PV, industrial distribution and auxiliary power systems that cross several installation environments. The unarmoured construction keeps the cable relatively straightforward to handle while the route design provides any additional impact or excavation protection that is required.

J/O Circuit Options

N2XY-J includes a green/yellow protective conductor; N2XY-O does not. Selecting the correct configuration together with conductor size and neutral requirements keeps the feeder’s core count, overall diameter and termination layout consistent with the electrical design. This avoids adding a separate protective conductor after the main cable route has already been planned.

Application Areas

Designed for Commercial PV systems, Utility auxiliary power, Building feeders and Underground distribution.

 

Commercial PV systems

Utility auxiliary power

Building feeders

Underground distribution

Technical Data

FAQ

Recommend

GENERAL DATA
  • Low-voltage XLPE-insulated power cable according to IEC 60502-1
  • Nominal voltage: AC U₀/U(Uₘ) 0.6/1(1.2) kV
  • Permissible conductor operating temperature: +90°C
  • Maximum short-circuit conductor temperature: +250°C for up to 5 s
  • Test voltage: 4 kV AC
  • Minimum bending radius, fixed installation: 12 × overall diameter

 

CABLE STRUCTURE
  • Copper conductor: IEC 60228 Class 1 or Class 2 depending on size
  • Insulation: cross-linked polyethylene (XLPE)
  • Core assembly / filler as required by cable configuration
  • Outer sheath: PVC
  • N2XY-J includes a green/yellow protective conductor; N2XY-O does not

 

TESTS
  • Conductor construction and resistance according to IEC 60228
  • Ozone resistance according to IEC 60811-403 where applicable to the insulation system
  • Hot-set and XLPE shrinkage tests according to IEC 60811-507 / IEC 60811-502
  • Impulse test according to IEC 60230
  • Ageing, high-temperature pressure, low-temperature and water-absorption tests according to the applicable IEC 60811 series

 

 

DIMENSIONS (NOMINAL)

 

Configuration Conductor type Insulation mm Sheath mm Nominal OD mm Approx. weight kg/km
1 × 16 RM 0.7 1.8 9.8 216
1 × 25 RM 0.9 1.8 11.5 318
1 × 35 RM 0.9 1.8 12.6 415
1 × 50 RM 1.0 1.8 14.1 543
1 × 70 RM 1.1 1.8 15.6 746
1 × 95 RM 1.1 1.8 17.6 1000
1 × 120 RM 1.2 1.8 19.2 1239
1 × 150 RM 1.4 1.8 21.2 1515
1 × 185 RM 1.6 1.8 23.1 1872
1 × 240 RM 1.7 1.8 25.8 2403
1 × 300 RM 1.8 1.8 27.8 2974
1 × 400 RM 2.0 1.9 31.1 3834
1 × 500 RM 2.2 2.0 34.9 4892
1 × 630 RM 2.8 2.8 46.6 6544
2 × 1.5 RE 0.7 1.8 10.1 145
2 × 2.5 RE 0.7 1.8 10.9 179
2 × 4 RE 0.7 1.8 11.8 226
2 × 6 RE 0.7 1.8 12.8 284
2 × 10 RM 0.7 1.8 15.0 416
2 × 16 RM 0.7 1.8 17.0 581
2 × 25 RM 0.9 1.8 20.4 859
2 × 35 RM 0.9 1.8 22.5 1109
3 × 1.5 RE 0.7 1.8 10.5 162
3 × 2.5 RE 0.7 1.8 11.4 205
3 × 4 RE 0.7 1.8 12.4 265
3 × 6 RE 0.7 1.8 13.4 338
3 × 10 RM 0.7 1.8 15.8 505
3 × 16 RM 0.7 1.8 18.0 719
3 × 25 RM 0.9 1.8 21.6 1072
3 × 35 RM 0.9 1.8 23.9 1403
3 × 50 SM 1.0 1.9 23.8 1581
4 × 1.5 RE 0.7 1.8 11.3 188
4 × 2.5 RE 0.7 1.8 12.2 240
4 × 4 RE 0.7 1.8 13.3 314
4 × 6 RE 0.7 1.8 14.5 408
4 × 10 RE 0.7 1.8 17.1 615
4 × 16 RE 0.7 1.8 19.6 885
4 × 25 RE 0.9 1.8 23.7 1330
4 × 35 RE 0.9 1.8 26.2 1758
4 × 50 SM 1.0 2.0 27.1 2082
4 × 70 SM 1.1 2.1 31.4 2937
4 × 95 SM 1.1 2.2 35.0 3955
4 × 120 SM 1.2 2.4 39.3 4979
4 × 150 SM 1.4 2.6 43.6 6129
4 × 185 SM 1.6 2.7 48.0 7591
4 × 240 SM 1.7 2.9 53.9 9875
5 × 1.5 RE 0.7 1.8 12.1 218
5 × 2.5 RE 0.7 1.8 13.1 281
5 × 4 RE 0.7 1.8 14.3 372
5 × 6 RE 0.7 1.8 15.6 486
5 × 10 RM 0.7 1.8 18.6 740
5 × 16 RM 0.7 1.8 21.3 1071
5 × 25 RM 0.9 1.8 25.9 1619
5 × 35 RM 0.9 1.8 28.8 2138
5 × 50 RM 1.0 2.1 29.4 2578
5 × 70 RM 1.1 2.2 33.7 3616
5 × 95 RM 1.1 2.4 38.6 4933
5 × 120 RM 1.2 2.5 42.6 6153
5 × 150 RM 1.4 2.7 47.7 7587
5 × 185 RM 1.6 2.9 52.8 9454
5 × 240 RM 1.7 3.1 58.7 12242

Dimensions vary by core arrangement; only the listed constructions are covered by this table.

 

Download TDS

Can NYY, N2XY and N2XH be treated as direct alternatives?

No. They can share the same 0.6/1 kV voltage class, but their insulation, sheath materials, fire behaviour and intended installation conditions differ. The required cable should follow the route and fire specification rather than the voltage rating alone.

Can you propose an aluminium alternative to a copper LV cable in our BOQ?

Yes, this can be reviewed, but aluminium is not normally a size-for-size replacement for copper. Current, route length, voltage drop, installation method, available space and the equipment termination system all need to be checked before an alternative size is proposed.

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.