H05V-R Stranded PVC Wire

H05V-R balances shape retention and easier routing for protected fixed wiring in panels, appliances and conduit.

Typical Scenarios
Key Specifications
  • Equipment internal wiring
  • Protected cabinet connections
  • Fixed low-voltage circuits
  • Enclosed electrical assemblies

 

  • Rated voltage: 300/500 V
  • Conductor: Class 2 stranded copper
  • Insulation: PVC
  • Maximum conductor temperature: +70°C
  • Design standard: EN 50525-2-31

 

Select cable specifications:
Certifications & complance:

Product Highlights

Moderate Wiring Flexibility

H05V-R uses a Class 2 stranded copper conductor to handle moderate bends more easily than solid H05V-U during equipment and enclosure wiring. It is useful where the route needs some forming around internal components but does not require the very fine strands of H05V-K. The benefit is easier installation while retaining a fixed-wiring construction.

Straightforward Class 2 Termination

The coarser Class 2 strands are easier to keep together during stripping and terminal preparation than a fine Class 5 bundle. With terminals suitable for stranded conductors, H05V-R gives installers a stable conductor end and predictable clamping for permanent connections. This is valuable where moderate flexibility is needed without adding unnecessary termination complexity.

Fixed-Wiring Boundary

A stranded conductor can look flexible without being intended for repeated movement. H05V-R is designed for permanent fixed wiring, so it suits circuits that are formed during installation and then remain stationary. Where the cable will move repeatedly in service, a purpose-designed flexible cable should be selected instead. This distinction helps prevent the wrong conductor class being used for the duty.

Application Areas

Designed for Electrical equipment, Control enclosures, Protected fixed circuits and Cabinet assemblies.

 

Electrical equipment

Control enclosures

Protected fixed circuits

Cabinet assemblies

Technical Data

FAQ

Recommend

GENERAL DATA
  • PVC single-core fixed wiring conductor according to EN 50525-2-31
  • Nominal voltage: AC U₀/U 300/500 V
  • Test voltage: 2000 V
  • Temperature range: +5°C to +70°C during installation; -30°C to +80°C when fixed
  • Maximum conductor operating temperature: +70°C

 

CABLE STRUCTURE
  • Bare copper conductor, stranded, IEC 60228 Class 2
  • Insulation: PVC compound type TI1 according to EN 50363-3

 

TESTS
  • Conductor resistance according to EN / IEC 60228
  • Flame propagation according to EN / IEC 60332-1-2
  • Voltage and insulation-resistance tests according to the applicable EN 50525 / EN 50395 test programme
  • PVC mechanical, ageing and thermal tests according to the applicable EN / IEC 60811 series

 

 

DIMENSIONS

 

Nominal size mm² Insulation mm Overall diameter range mm
1 × 0.5 0.6 2.0–2.4
1 × 0.75 0.6 2.2–2.6
1 × 1 0.6 2.3–2.8

Dimensions are nominal and may vary within the applicable product tolerance.

 

Download TDS

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.

Is there one MOQ for all HORNOUR cable products?

No single MOQ applies across the entire range. The practical quantity depends on the cable type, size, construction, packing and production conditions. Send the actual cable list and quantities and we can confirm the applicable requirement for those items.