NYM PVC Installation Cable

NYM provides compact multicore fixed wiring for dry, damp and protected indoor routes, walls and distribution boards.

Typical Scenarios
Key Specifications
  • Indoor building circuits
  • Distribution-board connections
  • Power and lighting wiring
  • Installation in walls and conduit

 

  • Rated voltage: 300/500 V
  • Conductor: Class 1 or Class 2 copper, by size
  • Insulation: PVC
  • Outer sheath: PVC
  • Application: fixed indoor installation

 

Select cable specifications:
Variant:
Certifications & complance:

Product Highlights

Fast Building Wiring

NYM combines several insulated copper conductors inside one PVC sheath for fixed 300/500 V building wiring. Instead of pulling individual wires through every route, installers can use one multicore cable for power, lighting and equipment circuits. This is particularly useful in walls, ducts, surface routes and other building installations where a compact sheathed cable reduces installation steps.

Walls, Ducts and Concrete

The NYM construction is intended for fixed domestic, commercial and industrial installation and can be laid in walls, ducting, cable trays and directly in concrete where local rules permit. This gives designers a broad indoor building-wiring option that can continue through several common construction methods without changing cable family.

J/O Circuit Options

NYM-J includes a green/yellow protective conductor; NYM-O does not. The choice lets the same 300/500 V cable family cover circuits with different earthing arrangements while keeping core count and terminal planning clear. Selecting the correct version at design stage avoids adding an extra protective conductor after the route has already been installed.

Application Areas

Designed for Indoor walls, Closed conduits, Distribution panels and Power and lighting circuits.

 

Indoor walls

Closed conduits

Distribution panels

Power and lighting circuits

Technical Data

FAQ

Recommend

GENERAL DATA
  • Fixed wiring cable according to DIN VDE 0281-1 / applicable NYM construction requirements
  • Nominal voltage: AC U₀/U 300/500 V
  • Maximum conductor operating temperature: +70°C
  • Test voltage: 2000 V
  • Intended for fixed installation in protected building routes; not for direct sunlight without additional UV protection

 

CABLE STRUCTURE
  • Bare copper conductor: IEC 60228 Class 1 solid or Class 2 stranded, depending on size
  • Core insulation: PVC
  • Cores laid together with filler / inner covering as required to maintain cable form
  • Outer sheath: PVC
  • NYM-J includes a green/yellow protective conductor; NYM-O does not

 

TESTS
  • Conductor construction and resistance according to IEC 60228
  • Flame propagation according to EN / IEC 60332-1-2
  • Voltage and insulation-resistance tests according to the applicable product standard
  • PVC mechanical, ageing and thermal tests according to the applicable EN / IEC 60811 series

 

 

DIMENSIONS

 

Configuration Conductor type Conductor OD mm Insulation mm Inner sheath mm Outer sheath mm Overall diameter mm Current in air A Copper weight kg/km Approx. cable weight kg/km
2 × 1.5 RE 1.6 0.7 0.4 1.2 8.7 17.5 29 125
2 × 2.5 RE 2.0 0.8 0.4 1.2 10.0 24 48 165
2 × 4 RE 2.5 0.8 0.4 1.2 11.0 32 77 215
2 × 6 RE 3.1 0.8 0.4 1.2 12.2 41 115 280
2 × 10 RE 4.0 1.0 0.6 1.4 15.4 57 192 455
2 × 16 RM 5.0 1.0 0.6 1.4 17.4 76 307 630
3 × 1.5 RE 1.6 0.7 0.4 1.2 9.1 17.5 43 135
3 × 2.5 RE 2.0 0.8 0.4 1.2 10.4 24 72 190
3 × 4 RE 2.5 0.8 0.4 1.2 11.8 32 115 258
3 × 6 RE 3.1 0.8 0.4 1.4 13.0 41 173 337
3 × 10 RE 4.0 1.0 0.6 1.4 15.9 57 288 528
3 × 16 RM 5.0 1.0 0.8 1.4 18.1 76 461 731
4 × 1.5 RE 1.6 0.7 0.4 1.2 9.8 17.5 58 160
4 × 2.5 RE 2.0 0.8 0.4 1.2 11.3 24 96 230
4 × 4 RE 2.5 0.8 0.4 1.4 13.0 32 154 330
4 × 6 RE 3.1 0.8 0.6 1.4 15.1 41 230 460
4 × 10 RE 4.0 1.0 0.6 1.4 17.6 57 384 680
4 × 16 RM 5.0 1.0 0.8 1.4 21.3 76 614 1048
5 × 1.5 RE 1.6 0.7 0.4 1.2 10.3 17.5 72 190
5 × 2.5 RE 2.0 0.8 0.4 1.2 12.0 24 120 270
5 × 4 RE 2.5 0.8 0.6 1.4 14.5 32 192 410
5 × 6 RE 3.1 0.8 0.6 1.4 16.1 41 288 540
5 × 10 RE 4.0 1.0 0.6 1.4 19.2 57 480 850
5 × 16 RM 5.0 1.0 0.8 1.6 23.4 76 768 1280

This table covers 2–5 core NYM constructions; 1-core NYM is not included.

 

Download TDS

Can MMJ replace NYM, or vice versa?

Not automatically. MMJ is specified in the Finnish market under SFS 2091, while NYM belongs to a different product and standards environment. The project specification, core arrangement, installation method and fire requirement should be checked before either cable is proposed as a substitute.

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.