NA2XS(F)2Y Medium-Voltage Power Cable – 12-20 kV

Reliable medium-voltage cable for commercial and industrial energy networks

Typical Scenarios
  • Commercial and industrial energy distribution networks (HDPE for exposed areas, MDPE for buried routing).
  • Connection between transformers, switchgear, and medium-voltage panels.
  • Routing through conduits or direct burial where mechanical protection is essential.
  • Projects requiring long service life under UV, moisture, and mechanical stress.
Select cable specifications:
Certifications & complance:

Product Highlights

Installation Environment

Suitable for industrial and commercial energy distribution, including direct burial, conduit, or exposed routing. Sheath choice: HDPE for UV exposure, MDPE for underground installations.

Performance & Durability

XLPE insulation and metallic sheath provide high dielectric strength and mechanical reliability. Resistant to moisture, UV, and mechanical stress, ensuring consistent performance.

Compliance & Safety

Certified CE, RoHS, REACH. Complies with international medium-voltage standards to minimize risk and ensure safety in industrial and commercial installations.

Application Areas

Compatible with transformers, switchgear, and medium-voltage cable accessories rated 12-20 kV.

Suitable for connection to industrial and commercial distribution networks.

Works with joints and terminations rated for 12-20 kV medium-voltage systems.

Technical Data

FAQ

Recommend

CABLE STRUCTURE
  • Aluminium,annealed stranded acc.to DIN VDE 0295 Class 2/IEC60228 Class 2
  • Conductor Screen:Semi-conductive material (bonded)
  • Insulation:Cross-Linked Polyethylene (XLPE)
  • Insulation Screen:Semi-conductive material (bonded)
  • Screen:Copper wires and copper tape
  • Outer sheath:MDPE
TESTS
  • Conductor construction and resistance acc.to lEC 60228
  • Partial discharge test acc. to IEC 60885-3
  • Hot set test acc. to lEC60811-507
  • Impulse test acc.to lEC60230
  • Ageing properties acc.to IEC60811-501 & IEC60811-401
  • Loss of mass test acc. to IEC60811-409
  • Pressure test at high temperature acc. to IEC60811-508
  • Low temperature test acc. to IEC60811-504 & IEC60811-505&IEC60811-506
  • Heat shock test acc. to IEC60811-509
  • Water absorption test acc.to IEC60811-402
  • WShrinkage test for XLPE insulation acc. to IEC60811-502
  • Water penetration test acc. to lEC60502-2 Annex F and Annex H



Description Cross Section
m㎡
OD of conductor mm Thickness of Semi- con . layer Inner mm Thickness of Semi- con . layer Outer mm Thickness of Insulation mm Wire Screen cross section
m㎡
Tape Screen Thickness mm Thickness of Sheath mm Cable overall diameter mm Cable weight kg/km
NA2XS(F)2Y 12/20(24)kV 1 x 50 8.1 0.7 0.7 5.5 16 0.1 1.8 27 700
NA2XS(F)2Y 12/20(24)kV 1 x 70 9.7 0.7 0.7 5.5 16 0.1 1.9 29 800
NA2XS(F)2Y 12/20(24)kV 1 x 95 11.4 0.7 0.7 5.5 16 0.1 1.9 31 900
NA2XS(F)2Y 12/20(24)kV 1 x 120 12.7 0.7 0.7 5.5 16 0.1 2 32 1000
NA2XS(F)2Y 12/20(24)kV 1 x 150 14.5 0.7 0.7 5.5 25 0.1 2 34 1300
NA2XS(F)2Y 12/20(24)kV 1 x 185 15.9 0.7 0.7 5.5 25 0.1 2.1 36 1400
NA2XS(F)2Y 12/20(24)kV 1 x 240 18.6 0.7 0.7 5.5 25 0.1 2.1 38 1600
NA2XS(F)2Y 12/20(24)kV 1 x 300 20.7 0.7 0.7 5.5 25 0.1 2.2 42 1900
NA2XS(F)2Y 12/20(24)kV 1 x 400 23.5 0.7 0.7 5.5 35 0.1 2.3 45 2250
NA2XS(F)2Y 12/20(24)kV 1 x 500 26.5 0.7 0.7 5.5 35 0.1 2.4 48 2750
NA2XS(F)2Y 12/20(24)kV 1 x 630 30.2 0.7 0.7 5.5 35 0.1 2.5 52 3250

Download TDS

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.

Can LV and MV cables be supplied in the drum lengths shown in our cable schedule?

Requested drum lengths can be reviewed with the cable schedule. What is practical depends on cable dimensions and weight, total quantity, drum capacity and transport or site-handling limits, so the required lengths should be included with the enquiry.

Is there one MOQ for all HORNOUR cable products?

No single MOQ applies across the entire range. The practical quantity depends on the cable type, size, construction, packing and production conditions. Send the actual cable list and quantities and we can confirm the applicable requirement for those items.