NYCWY Power Cable

Copper Conductor Wire Armored Cable for Industrial & Commercial Installations

Typical Scenarios
  • Industrial plants and factories where mechanical protection is required
  • Commercial buildings with exposed or semi-exposed cable routes
  • Applications requiring reliable protective earth via concentric conductor
  • Power distribution to machinery, lighting, and energy feeders
Select cable specifications:
Certifications & complance:

Product Highlights

Galvanized steel wire armor shields the cable against mechanical stress, ensuring safe operation in industrial environments.

Galvanized steel wire armor shields the cable against mechanical stress, ensuring safe operation in industrial environments.

Concentric Conductor for Grounding

The concentric copper conductor serves as a protective earth, offering an extra layer of electrical safety for installers and operators.

Durable Flame-Retardant Insulation

PVC or halogen-free insulation provides heat resistance, chemical resistance, and fire safety compliance for industrial and commercial installations.

Application Areas

Compatible with switchgear, distribution boards, and energy panels

Suitable for conduits, trays, and exposed building routes

Works with standard cable lugs, glands, and grounding systems

Ensures safe integration in industrial grounding and earthing networks

Technical Data

FAQ

Recommend

CABLE STRUCTURE
  • Copper conductor acc.to DIN VDE 0295 cl.1 or cl.2/IEC60228 Class 1 or Class 2
  • Insulation:PVC(type DN4 acc.to HD603 S1)
  • Assembly:Filler for roundness,Nonwoven tape overlapped
  • Inner sheath:PVC (type DMV5 acc.to HD603 S1)
  • Screen Copper wire and copper tape screen
  • Outer sheath:PVC(type DMV5 acc.to HD603 S1)
  • Marking:
    HORNOUR NYCWY 0.6M1kV nxsection'mm2 CUPVC/PVC/CWS/CTS/PVC
    VDE0276-6031HD603S1/IEC60502-1m

 

TESTS
  • Conductor construction and resistance acc.to IEC 60228
  • Heat shock test acc.to IEC60811-509
  • Impulse test acc.to IEC60230
  • Ageing properties acc.to IEC60811-501 IEC60811-401
  • Loss of mass test acc.to IEC60811-409
  • Pressure test at high temperature acc.to IEC60811-508
  • Low temperature test acc.to IEC60811-504 IEC60811-505&lEC60811-506
  • Water absorption test acc.to IEC60811-402



Description Cross Section m㎡ Conduct or Type mm Thickness of Insulation mm Thickness of Inner sheath mm Screen cross section m㎡ Thickness of Sheath mm Cable overall diameter mm Current carrying capacity
In ground 20°C A
Current carrying capacity
In air 30°C A
Cable weight kg/km
NYCWY 2 x 10 / 10 RE 1 1 10 1.8 19 79 60 650
NYCWY 2 x 16 / 16 RE 1 1 16 1.8 21 102 80 850
NYCWY 2 x 25 / 25 RM 1.2 1 25 1.8 24 133 106 1210
NYCWY 3 x 10 / 10 RE 1 1 10 1.8 21 79 60 730
NYCWY 3 x 16 / 16 RE 1 1 16 1.8 22 102 80 1000
NYCWY 3 x 25 / 16 RM 1.2 1 16 1.8 28 133 106 1550
NYCWY 3 x 25 / 25 RM 1.2 1 25 1.8 28 133 106 1600
NYCWY 3 x 35 / 16 RM 1.2 1 16 1.9 28.5 160 129 1750
NYCWY 3 x 35 / 35 SM 1.2 1 35 1.9 28.5 160 129 1850
NYCWY 3 x 50 / 25 SM 1.4 1 25 2 31.5 190 157 2250
NYCWY 3 x 50 / 50 SM 1.4 1 50 2 31.5 190 157 2450
NYCWY 3 x 70 / 35 SM 1.4 1.2 35 2.1 35.5 234 199 2950
NYCWY 3 x 70 / 70 SM 1.4 1.2 70 2.1 36.5 234 199 3350
NYCWY 3 x 95 / 50 SM 1.6 1.2 50 2.3 40.5 280 249 4100
NYCWY 3 x 95 / 95 SM 1.6 1.2 95 2.3 40.5 280 249 4500
NYCWY 3 x 120 / 70 SM 1.6 1.2 70 2.3 43.5 319 289 5050
NYCWY 3 x 120 / 120 SM 1.6 1.2 120 2.4 44.5 319 289 5550
NYCWY 3 x 150 / 70 SM 1.8 1.4 70 2.5 47.5 357 329 6000
NYCWY 3 x 150 / 150 SM 1.8 1.4 150 2.5 48.5 357 329 6900
NYCWY 3 x 185 / 95 SM 2 1.4 95 2.6 50 402 377 7550
NYCWY 3 x 185 / 185 SM 2 1.4 185 2.6 51 402 377 8500
NYCWY 3 x 240 / 120 SM 2.2 1.4 120 2.8 57 463 443 9950
NYCWY 4 x 10 / 10 RE 1 1 10 1.8 22 79 60 890
NYCWY 4 x 16 / 16 RE 1 1 16 1.8 25 102 80 1250
NYCWY 4 x 25 / 16 RM 1.2 1 16 1.9 30.5 133 106 1800
NYCWY 4 x 35 / 16 SM 1.2 1 16 2 31.5 160 129 2050
NYCWY 4 x 50 / 25 SM 1.4 1.2 25 2.1 35.5 190 157 2700
NYCWY 4 x 70 / 35 SM 1.4 1.2 35 2.2 39.5 234 199 3750
NYCWY 4 x 95 / 50 SM 1.6 1.2 50 2.3 43.5 280 249 5000
NYCWY 4 x 120 / 70 SM 1.6 1.4 70 2.6 49.5 319 289 6350
NYCWY 4 x 150 / 70 SM 1.8 1.4 70 2.6 51 357 329 7650
NYCWY 4 x 185 / 95 SM 2 1.4 95 2.8 56 402 377 9350
NYCWY 4 x 240 / 120 SM 2.2 1.6 120 3 62.5 463 443 11600

Download TDS

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.

Can LV and MV cables be supplied in the drum lengths shown in our cable schedule?

Requested drum lengths can be reviewed with the cable schedule. What is practical depends on cable dimensions and weight, total quantity, drum capacity and transport or site-handling limits, so the required lengths should be included with the enquiry.

Is there one MOQ for all HORNOUR cable products?

No single MOQ applies across the entire range. The practical quantity depends on the cable type, size, construction, packing and production conditions. Send the actual cable list and quantities and we can confirm the applicable requirement for those items.