Please fill out the form below to obtain the download document(s) you need
Notice: By submitting this form. you confirm that you have read and accepted our Privacy Policy (link toPrivacy Policy). We will contact you within 24 hours of receiving your request.

EN

LME Metal Price
Metal Exchange Prices
Metal Rate
Copper € 1,261.52 / 100kg
Copper (MK) € 1,389.12 / 100kg
MS58 € 1,074.00 / 100kg
Al € 412.52 / 100kg
Ni € 1,571.63 / 100kg
Ag € 2,046.80 / 1,000g
Gold € 116,900.00 / 1,000g
Quotes as of: 15.09.2026
All information is provided without guarantee or liability.

Not sure which cable to choose?
Explore Cable Selection Guide

Request Engineering Support

NA2XH Power Cable

XLPE Insulated and PVC Sheathed Heavy-Duty Power Cable for Commercial & Industrial Applications

Typical Scenarios
  • Main and subpanel distribution in commercial and industrial facilities
  • Fixed routing through cable trays, conduits, or protected underground ducts
  • Heavy-duty industrial feeders and machinery power connections
  • Electrical infrastructure requiring reliable long-term operation and compliance
Select cable specifications:
Certifications & complance:

Product Highlights

High Electrical Performance

XLPE insulation improves dielectric properties, reduces power loss, and allows stable operation at higher temperatures. This ensures safe and efficient power delivery for high-demand industrial networks.

Robust Construction for Heavy-Duty Use

Copper conductors with XLPE insulation and PVC sheathing provide mechanical and electrical robustness, protecting against bending stress, UV exposure, and environmental factors. Suitable for industrial, commercial, and infrastructure installations.

Compliance & Safety Assurance

Certified to internationally recognized standards, NA2XH cables meet electrical safety regulations and flame-retardant requirements, ensuring reduced project risk and easier regulatory acceptance.

Application Areas

Compatible with industrial switchgear, transformers, and distribution boards

Works with standard connectors, cable glands, and terminations

Suitable for cable trays, conduits, and underground routes

Designed for integration into commercial and industrial electrical distribution systems

Technical Data

FAQ

Recommend

CABLE STRUCTURE
  • Aluminium,annealed stranded acc.to DIN VDE 0295 Class 2/IEC60228 Class 2
  • Insulation:Cross-Linked Polyethylene (XLPE)Outer sheath PVC(Polyvinyl Chloride)

 

TESTS
  • Conductor construction and resistance acc.to IEC 60228
  • Ozone resistance acc.to IEC60811-403
  • Hot set test acc.to IEC60811-507
  • Impulse test acc.to IEC60230
  • Ageing properties acc.to IEC60811-501 IEC60811-401
  • Loss of mass test acc.to lEC60811-409
  • Pressure test at high temperature acc.to IEC60811-508
  • Low temperature test acc.to IEC60811-504 IEC60811-505&IEC60811-506
  • Heat shock test acc.to IEC60811-509
  • Water absorption test acc.to IEC60811-402
  • Shrinkage test for XLPE insulation acc.to IEC60811-502
  • Water penetration test acc.to IEC60502-2 Annex F and Annex H



Description Cross Section
m㎡
OD of conductor mm Thickness of Insulation mm Thickness of Sheath mm Cable overall diameter mm Current Capaciy in air A Alu weight kg/km Cable weight kg/km
NA2XY 0.6/1(1.2)kV 1 x 25 6.3 0.9 1.4 11.7 136 72.5 132
NA2XY 0.6/1(1.2)kV 1 x 35 7.1 0.9 1.4 12.5 166 101.5 166
NA2XY 0.6/1(1.2)kV 1 x 50 8.1 1 1.4 13.6 205 145 211
NA2XY 0.6/1(1.2)kV 1 x 70 9.7 1.1 1.4 15.5 260 203 283
NA2XY 0.6/1(1.2)kV 1 x 95 11.4 1.1 1.5 17.4 321 275.5 376
NA2XY 0.6/1(1.2)kV 1 x 120 12.7 1.2 1.5 19 376 348 456
NA2XY 0.6/1(1.2)kV 1 x 150 14.5 1.4 1.6 22 431 435 560
NA2XY 0.6/1(1.2)kV 1 x 185 15.9 1.6 1.7 23.9 501 536.5 697
NA2XY 0.6/1(1.2)kV 1 x 240 18.6 1.7 1.8 27 600 696 878
NA2XY 0.6/1(1.2)kV 1 x 300 20.7 1.8 1.9 29.5 696 870 1073
NA2XY 0.6/1(1.2)kV 1 x 400 23.5 2 2 32.9 821 1160 1347
NA2XY 0.6/1(1.2)kV 1 x 500 26.5 2.2 2.1 36.6 971 1450 1705
NA2XY 0.6/1(1.2)kV 1 x 630 30.2 2.4 2.2 41 1151 1827 2705

Download TDS

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.

Can LV and MV cables be supplied in the drum lengths shown in our cable schedule?

Requested drum lengths can be reviewed with the cable schedule. What is practical depends on cable dimensions and weight, total quantity, drum capacity and transport or site-handling limits, so the required lengths should be included with the enquiry.

Is there one MOQ for all HORNOUR cable products?

No single MOQ applies across the entire range. The practical quantity depends on the cable type, size, construction, packing and production conditions. Send the actual cable list and quantities and we can confirm the applicable requirement for those items.