N2XY Power Cable

XLPE Insulated and PVC Sheathed 0.6/1 kV Power Cable for Commercial & Industrial Distribution

Typical Scenarios
  • Power distribution between main panels, subpanels, and industrial loads
  • Fixed installations in factories, warehouses, commercial buildings, and infrastructure
  • Underground cable trenches with mechanical protection (when required)
  • Energy distribution feeders in highdemand electrical networks
Certifications & complance:

Product Highlights

High Electrical Performance

XLPE insulation enhances dielectric properties and thermal stability, allowing N2XY cables to operate reliably at higher continuous temperatures. This results in improved current carrying capacity and reduced electrical losses compared with standard PVC insulated cables.

Robust Structure for Commercial & Industrial Use

Copper conductors and XLPE insulation provide strong mechanical and electrical performance. The PVC outer sheath protects the cable from environmental exposure, mechanical stress, and installation wear, suitable for cable trays, conduits, and underground ducts when properly protected.

Compliant & Safe Infrastructure Wiring

Designed in accordance with internationally accepted power cable standards, N2XY cables support safe and compliant electrical distribution. Certifications and flameretardant performance improve project acceptance and reduce onsite safety risks.

Application Areas

Compatible with industrial distribution boards and switchgear

Integrates with transformers, power panels, and cable route systems

Works with standard cable glands, connectors, and termination systems

Suitable for cable trays, conduits, and protected underground installations

Supports building power networks, industrial plants, and electrical infrastructure

Technical Data

FAQ

Recommend

CABLE STRUCTURE
  • Aluminium,annealed stranded acc.to DIN VDE 0295 Class 2/IEC60228 Class 2
  • Insulation:Cross-Linked Polyethylene (XLPE)Outer sheath PVC(Polyvinyl Chloride)

 

TESTS
  • Conductor construction and resistance acc.to IEC 60228
  • Ozone resistance acc.to IEC60811-403
  • Hot set test acc.to IEC60811-507
  • Impulse test acc.to IEC60230
  • Ageing properties acc.to IEC60811-501 IEC60811-401
  • Loss of mass test acc.to lEC60811-409
  • Pressure test at high temperature acc.to IEC60811-508
  • Low temperature test acc.to IEC60811-504 IEC60811-505&IEC60811-506
  • Heat shock test acc.to IEC60811-509
  • Water absorption test acc.to IEC60811-402
  • Shrinkage test for XLPE insulation acc.to IEC60811-502
  • Water penetration test acc.to IEC60502-2 Annex F and Annex H



Description Cross Section
m㎡
OD of conductor mm Thickness of Insulation mm Thickness of Sheath mm Cable overall diameter mm Current Capaciy in air A Alu weight kg/km Cable weight kg/km
NA2XY 0.6/1(1.2)kV 1 x 25 6.3 0.9 1.4 11.7 136 72.5 132
NA2XY 0.6/1(1.2)kV 1 x 35 7.1 0.9 1.4 12.5 166 101.5 166
NA2XY 0.6/1(1.2)kV 1 x 50 8.1 1 1.4 13.6 205 145 211
NA2XY 0.6/1(1.2)kV 1 x 70 9.7 1.1 1.4 15.5 260 203 283
NA2XY 0.6/1(1.2)kV 1 x 95 11.4 1.1 1.5 17.4 321 275.5 376
NA2XY 0.6/1(1.2)kV 1 x 120 12.7 1.2 1.5 19 376 348 456
NA2XY 0.6/1(1.2)kV 1 x 150 14.5 1.4 1.6 22 431 435 560
NA2XY 0.6/1(1.2)kV 1 x 185 15.9 1.6 1.7 23.9 501 536.5 697
NA2XY 0.6/1(1.2)kV 1 x 240 18.6 1.7 1.8 27 600 696 878
NA2XY 0.6/1(1.2)kV 1 x 300 20.7 1.8 1.9 29.5 696 870 1073
NA2XY 0.6/1(1.2)kV 1 x 400 23.5 2 2 32.9 821 1160 1347
NA2XY 0.6/1(1.2)kV 1 x 500 26.5 2.2 2.1 36.6 971 1450 1705
NA2XY 0.6/1(1.2)kV 1 x 630 30.2 2.4 2.2 41 1151 1827 2705

Download TDS

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.

Can LV and MV cables be supplied in the drum lengths shown in our cable schedule?

Requested drum lengths can be reviewed with the cable schedule. What is practical depends on cable dimensions and weight, total quantity, drum capacity and transport or site-handling limits, so the required lengths should be included with the enquiry.

Is there one MOQ for all HORNOUR cable products?

No single MOQ applies across the entire range. The practical quantity depends on the cable type, size, construction, packing and production conditions. Send the actual cable list and quantities and we can confirm the applicable requirement for those items.