N2XH Power Cable

Halogen-Free XLPE Insulated 0.6/1 kV Power Cable

Typical Scenarios
  • Power distribution in commercial buildings and office complexes
  • Electrical installations in public facilities such as hospitals, airports, and transport hubs
  • Industrial plants requiring reduced smoke emission during fire events
  • Infrastructure installations where halogen-free cables are specified for safety compliance
Certifications & complance:

Product Highlights

Low Smoke Halogen-Free Safety Performance

The halogen-free sheath significantly reduces toxic and corrosive gas emissions during fire exposure. This improves safety for occupants and helps protect electronic equipment and building infrastructure.

XLPE Insulation for Stable Electrical Performance

Cross-linked polyethylene insulation provides improved dielectric strength and thermal resistance compared with traditional PVC insulation. This supports reliable power transmission in modern building energy systems.

Designed for Safety-Critical Installations

N2XH cables are commonly specified in projects where fire safety and evacuation conditions are important considerations. Their construction supports safe operation in commercial and industrial electrical infrastructure.

Application Areas

Compatible with building power distribution systems and electrical panels

Suitable for installation in cable trays, conduits, and building infrastructure

Works with standard termination systems, cable glands, and connectors

Compatible with switchgear, transformers, and distribution boards

Suitable for commercial buildings, public facilities, and industrial electrical networks

Technical Data

FAQ

Recommend

CABLE STRUCTURE
  • Aluminium,annealed stranded acc.to DIN VDE 0295 Class 2/IEC60228 Class 2
  • Insulation:Cross-Linked Polyethylene (XLPE)Outer sheath PVC(Polyvinyl Chloride)

 

TESTS
  • Conductor construction and resistance acc.to IEC 60228
  • Ozone resistance acc.to IEC60811-403
  • Hot set test acc.to IEC60811-507
  • Impulse test acc.to IEC60230
  • Ageing properties acc.to IEC60811-501 IEC60811-401
  • Loss of mass test acc.to lEC60811-409
  • Pressure test at high temperature acc.to IEC60811-508
  • Low temperature test acc.to IEC60811-504 IEC60811-505&IEC60811-506
  • Heat shock test acc.to IEC60811-509
  • Water absorption test acc.to IEC60811-402
  • Shrinkage test for XLPE insulation acc.to IEC60811-502
  • Water penetration test acc.to IEC60502-2 Annex F and Annex H



Description Cross Section
m㎡
OD of conductor mm Thickness of Insulation mm Thickness of Sheath mm Cable overall diameter mm Current Capaciy in air A Alu weight kg/km Cable weight kg/km
NA2XY 0.6/1(1.2)kV 1 x 25 6.3 0.9 1.4 11.7 136 72.5 132
NA2XY 0.6/1(1.2)kV 1 x 35 7.1 0.9 1.4 12.5 166 101.5 166
NA2XY 0.6/1(1.2)kV 1 x 50 8.1 1 1.4 13.6 205 145 211
NA2XY 0.6/1(1.2)kV 1 x 70 9.7 1.1 1.4 15.5 260 203 283
NA2XY 0.6/1(1.2)kV 1 x 95 11.4 1.1 1.5 17.4 321 275.5 376
NA2XY 0.6/1(1.2)kV 1 x 120 12.7 1.2 1.5 19 376 348 456
NA2XY 0.6/1(1.2)kV 1 x 150 14.5 1.4 1.6 22 431 435 560
NA2XY 0.6/1(1.2)kV 1 x 185 15.9 1.6 1.7 23.9 501 536.5 697
NA2XY 0.6/1(1.2)kV 1 x 240 18.6 1.7 1.8 27 600 696 878
NA2XY 0.6/1(1.2)kV 1 x 300 20.7 1.8 1.9 29.5 696 870 1073
NA2XY 0.6/1(1.2)kV 1 x 400 23.5 2 2 32.9 821 1160 1347
NA2XY 0.6/1(1.2)kV 1 x 500 26.5 2.2 2.1 36.6 971 1450 1705
NA2XY 0.6/1(1.2)kV 1 x 630 30.2 2.4 2.2 41 1151 1827 2705

Download TDS

Can you check an equivalent cable from another manufacturer?

Yes. Send the exact cable designation and, where possible, the existing datasheet or project specification. We compare conductor material, construction, voltage rating, standards and the requirements that affect the installation before confirming whether an equivalent can be offered.

What if the required size, core count or construction is not shown on the website?

Send the exact requirement. The website does not represent every possible production combination. We will check whether the construction can be supplied and whether the required standards or certification scope also cover that version before it is quoted.

Can LV and MV cables be supplied in the drum lengths shown in our cable schedule?

Requested drum lengths can be reviewed with the cable schedule. What is practical depends on cable dimensions and weight, total quantity, drum capacity and transport or site-handling limits, so the required lengths should be included with the enquiry.

Is there one MOQ for all HORNOUR cable products?

No single MOQ applies across the entire range. The practical quantity depends on the cable type, size, construction, packing and production conditions. Send the actual cable list and quantities and we can confirm the applicable requirement for those items.